Fire Alarms London
Morgan Fire protection specialises in fire alarms London systems, offering expert advice as to you fire alarm requirements, plus fire alarm system supply and installation.
The legal requirement for fire alarm systems
The Regulatory Reform (Fire Safety) Order 2005 requires that premises must be equipped with appropriate fire detectors and alarms. Automatic fire detection will also be needed in certain circumstances, such as premises where people sleep.
There are very specific fire system requirements depending on the type and use of your building plus the occupants within it. Morgan Fire offers expert advice as to the systems that will need to be employed within your building, systems that will meet your legal obligations plus your objectives and resources as the building manager / owner.
Many Fire Alarm System Options
There are numerous options for fire systems today with different manufacturers and suppliers offering many different product types and solutions. Morgan Fire will help you to navigate through this sea of options to a system that will meets your needs and budget.
Regular Fire Alarm System Testing and Maintenance
There are numerous requirements for the building manager / owner to regularly test and maintain an installed fire alarm system. The simple reason being so the system does work in case of an emergency. As part of the design / consultation process with Morgan Fire we will advise as to the testing and maintenance that is required, and undertake this process for many of our clients.
Fire Alarms London Components
There are many system components and options available for buildings that meet your legal requirements, these include (but are not limited too):
Fire Alarms and Detectors
C-Tec conventional fire alarm control panel
Complies fully with EN54:Parts 2 & 4
- Four conventional sounder circuits.
- Class change and alert inputs.
- Wide range of engineering functions including zone test,
non-latching zones, programmable delays and coincidence.
- Ancillary connections for up to eight two-wired repeaters per system and operational CFP relay boards
Apollo Series 65 Detectors
Apollo Series 65 smoke detectors and heat detectors
Apollo XP95 addressable detectors.
Approved to EN54-7:2000 or EN54-5:2000
- Conventional detectors housed in an attractive white polycarbonate case.
- Packaging designed to act as dust cover until commissioning
of system.
- Externally visible LED illuminates when detector changes to alarm state.
- 9.33v supply voltage.
KAC MCP Manual Call Point
EN54 compliant in any format
- Modern stylish design provides increased aesthetic appeal.
- Test, reset and lid release facility – in one combined tool.
- Plug in termination for faster wiring and installation.
- Can be used as either break glass or resettable call point. Fully compatible with all current KAC mounting accessories.
Electronic Solenoid Bell
- 6” bell available in 24v dc and 220/240v ac versions.
- Four-way terminal block provided for looping in and out.
- Designed for single fast installation with components that easily clip together. Base suitable for surface wiring without need for surface box or pat tress.
Fire Alarms London Product Guide
Morgan Fire Protection offers you a complete service of fire alarm system and emergency lighting testing and servicing in accordance with BS5839 Part1: 2002 (Fire Alarm Systems). Please contact Us for further details.